- Shorten start-up and batch cycles; systemize bypass blowdown
- Free Float® steam traps with a built-in bypass valve
FEATURES
SPECIFICATIONS
DRAWINGS & DOCUMENTS
- Space-saving Design
- The integral bypass valve eliminates the need for a separate bypass line, thereby saving space at the trap installation.
- Reduced Pipeline Costs
- Installation costs are reduced, as neither a bypass valve nor bypass piping are required.
- Energy Conservation
- Utilizes the TLV Free Float®. The combination of the valve opening being under a continuous water-seal and the 3-point float seating prevents steam leakage.
- Long Service Life
- The spherical Free Float® rotates, allowing any point on its surface to act as the valve seal and thus ensuring long service life.
- Inline Trap Maintenance
- Maintenance is possible without removing the trap from the piping. For disassembly and cleaning, simply remove the four bolts securing the cover of the trap.
- *1: Can be used to eliminate steam locking
- PMO = Maximum Operating Pressure
- TMO = Maximum Operating Temperature